Release Notes 1.21.0.1

Documentation, downloads and support

Release Notes 1.22.0.1

Documentation, downloads and support

Release Notes 1.23.0.1

Documentation, downloads and support

Release Notes 1.24.0.1

Documentation, downloads and support

Heading

The most open EMS


Dear Partner,

We’d like to inform you that software version 1.24.0.1 will be rolled out soon!
If auto-updates are enabled, the rollout happens automatically and requires no manual action from you. If you have questions or need assistance, simply reply to this email or contact our support team via the support portal.

Software version 1.24.0.1

New Integrations

These devices are now supported in SmartgridOne. This means their measurements can be read into SmartgridOne, and where applicable, they can be used in monitoring and control strategies.

Gotion - ESC Inverters


Added support for the Gotion ESC inverter range so inverter data can be monitored and used by the controller.

Read the Gotion docs →

KStar - Bluespark Series Inverter

Added support for KStar Bluespark models so they can be onboarded and monitored in SmartgridOne.

Read the Kstar docs →

FoxESS - H3 AIO

Added support for the FoxESS H3 all-in-one systems so production, battery, and status data can be monitored and used for control.

Read the FoxESS docs →

AlphaESS - TB125 and Storion G3

Added support for these AlphaESS models so battery and inverter values can be monitored and used in energy strategies.

Read the AlphaESS docs →

Solis - V2 hybrid inverters

Added support for the newest version of the Solis Hybrid Inverters protocol, enhancing the the battery control and allowing curtailment

Read the Solis docs →

Solinteg - V2 hybrid inverters

Added support for the Solinteg V2 driver so these hybrid systems can be onboarded and monitored.

Read the Solinteg docs →

Growatt - WIT 15K-HU

Added support for the Growatt WIT 15K-HU so measurements and control capabilities can be used in SmartgridOne.

Read the Growatt docs →

Sessy - Battery through API

Added API integration support for Sessy so battery status and control can be integrated into SmartgridOne.

Read the Sessy docs →

Huawei - SUN2000 Hybrid Energy Mete

Added support for the Huawei hybrid energy meter so grid import and export and site energy flows are available in SmartgridOne.

Read the Huawei docs →

Marstek - Venus-C Hybrid Inverter
(TCP protocol)

Added support via TCP so the controller can read values and integrate the inverter into monitoring.

Read the Marstek docs →

Socomec - Countis E27 energy meters

Added support for Countis E27 meters to read energy and power values into SmartgridOne.

Read the Socomec docs →

MyEnergi - Zappi Chargers

Added support for MyEnergi Zappi chargers so charging sessions and control can be integrated into SmartgridOne.

Read the MyEnergi docs →

Autel - Maxicharge DC EV-chargers

Added support for Autel DC chargers so charger status, measurements, and control can be integrated.

Read the Autel docs →

Volt-time - EV-Charging Station

Added support for Volt-time API V3 so Voltime-connected devices can be integrated more broadly and consistently.

Read the Volt-time docs →

Octave.energy- Cabinet V040

Added support for Octave Cabinet V040 so measurements and system status can be integrated in SmartgridOne.

Read the Octave.energy docs →

Akkusys - Relay-controlled heat pump

Added support for controlling heat pumps through an Akkusys relay setup so loads can be switched based on schedules and energy conditions.

Read the Akkusys docs →

New Features

System health logging for troubleshooting

The controller now logs disk usage, memory usage, and system load. This makes it easier to diagnose performance issues and speed up support investigations.

Italian language in the commissioning interface

The commissioning interface now supports Italian, making setup easier for Italian-speaking installers and customers.

Diagnostics test for External Signals

Added a diagnostic test option for External Signals, so installers can validate signal configuration more easily during commissioning.

Device physical settings management (internal feature)

Added internal tooling to manage device physical settings more consistently. This helps improve reliability and support workflows.

Base class for Modbus External Signals

Added a new Modbus External Signal foundation that improves consistency and makes it easier to extend Modbus signal support going forward.

MQTT External Signals now store logs locally

MQTT External Signals now write log files locally on the controller. This provides clearer troubleshooting data when investigating signal issues.

EV charger minimum and maximum charge current settings

Added settings to define a minimum and maximum charging current for EV chargers. This helps match charging behavior to site constraints and hardware limits.

Table of contents step when adding an External Signal

Added a clearer overview step when adding an External Signal, so installers can see what will be configured and what is still required.

Warnings for non-recommended datalogger and scheduler periods

The commissioning interface now warns when datalogger or scheduler intervals are set to unusual values. This helps avoid performance issues and unexpected behavior.

Improvements

Security

  • Two factor authentication in the commissioning interface
    • Added 2FA support in the commissioning interface to better protect accounts.
  • More secure communication for Enphase Gateway IQ

    • The Enphase Gateway IQ driver now uses HTTPS instead of HTTP.

System & Usability Improvements

  • System health logging for troubleshooting
    • The controller now logs disk usage, memory usage, and system load. This helps diagnose performance issues faster.
  • Italian language in the commissioning interface
    • Added Italian as a supported language during commissioning.
  • External Signals diagnostic test
    • Added a diagnostics test for External Signals so installers can verify signal setup more easily.
  • Clearer External Signal setup flow
    • Added a table of contents step when adding an External Signal, making the setup steps easier to follow.
  • Warnings for uncommon datalogger and scheduler settings
    • The interface now warns when datalogger or scheduler periods are set to non-recommended values. This helps prevent performance issues and unexpected behaviour.
  • Less load on the data page by default
    • Auto-refresh on the data page is now disabled by default, improving usability on slower connections and reducing unnecessary system load.
  • Cloud controller sites now include a data page
    • Added the data page for cloud controller sites to make site data easier to access.
  • Clearer logging when removing cloud controller sites
    • Improved logging when removing a site from a cloud controller, making support and auditing easier.
  • More reliable metadata handling for networked drivers
    • Cleaned up the metadata retrieval process for socket and HTTP drivers, improving consistency and stability.
  • More stable HTTP communication
    • Added timeouts to HTTP drivers to prevent hanging connections and improve reliability.
  • Cleaner reactive power readings
    • Improved filtering of outlier values for reactive power measurements, reducing spikes in graphs and dashboards.
  • Better validation during driver startup
    • Added validation for nodeId formatting across drivers.
    • Added validation of register naming during driver initialization to prevent configuration issues.
  • Improved scheduler explanations and feedback
    • Improved the MQTT scheduler explanations so settings are easier to understand.
    • Added a new scheduler label when no solution is found, so the user gets clearer feedback.
  • Translations update
    • General translation updates across the interface.
  • Development devices cleanup (internal)
    • Development devices have been cleaned up and reorganized to reduce clutter.

Device & Driver Enhancements

  • FoxESS driver improvements
    • Improved the FoxESS H3 driver and added support for more inverter models to the FoxESS H1 driver.
  • Growatt TL-X measurement handlin
    • The Growatt TL-X driver now uses the default measurement update logic for more consistent behaviour.
  • SAJ H1 onboarding & Standby Behaviour improvements
    • The SAJ H1 driver now asks whether a battery is present when adding the inverter. This prevents incorrect assumptions during setup.
    • Improved how the SAJ H1 battery standby setpoint is applied.
  • Sungrow Powerstack safer alarm behaviour
    • The controller now sends a stop command to Sungrow Powerstack if the inverter is in alarm.
  • GoodWe ESS export limit increased
    • GoodWe ESS now allows export up to 50 kW where supported.
  • Easee charging behaviour improved when not controlling
    • The Easee driver now sets the maximum charge current when SmartgridOne is not actively controlling, improving predictability.
  • Growatt VPP improvements
    • Improved serial number reading.
    • The driver now asks whether PV and battery are present during onboarding, improving configuration correctness.
  • SCU Container battery value reading improved
    • Improved reading of battery values for more reliable monitoring.
  • Frank Energie external signal supports larger batteries
    • Frank Energie external signal now supports batteries up to 100 kW.
  • External signal power limit calculations improved
    • Improved calculation of maximum charge and maximum discharge power for external signals so limits are applied more accurately.
  • Tecloman meter readings improved
    • Improved voltage and current reading for Tecloman meters.
  • Sofar Hybrid inverter PV power accuracy improved
    • The driver now reads PV Total Power instead of calculating it.
  • MyStrom Switch is more resilient to network issues
    • Improved handling of temporary network issues to reduce disconnects.
  • Sinexcel Isuna compatibility checks added
    • Added a compatibility check to avoid onboarding unsupported devices.
  • GoodWe ESS older models provide more battery detail
    • Older model driver now reads BMS status and battery maximum charge and discharge current.
  • BlitzPower driver now reads charger model
    • The BlitzPower driver now reads the charger model to improve device identification.
  • Deye battery configuration protected
    • Limited the number of Deye batteries to 2 per inverter to prevent unstable setups.
  • AlphaESS reliability improvements
    • AlphaESS Smile command timeout increased to 3 minutes.
    • Improved timeout handling for AlphaESS G2 and G3 drivers.
  • More logs for OCPP troubleshooting
    • Added logs for OCPP drivers to make charger troubleshooting easier.
  • Deye Sun single phase behaviour adjusted
    • The Deye Sun single phase hybrid inverter driver now prioritizes load first.

Other

  • MQTT external signals logging stored locally
    • MQTT External Signals now store logs in local files on the controller, which makes troubleshooting much easier.
  • Base class for Modbus external signals
    • Added a new Modbus External Signals base layer that improves consistency and enables easier expansion in future releases.
  • Internal support for managing physical device settings
    • Added internal support for managing device physical settings in a structured way, improving long-term maintainability.
Training sessions
We are also offering training sessions and webinars on SmartgridOne. Feel free to send me a reply if you'd like to register, you can find the schedule on our website and socials.

Presentatie afbeelding
Enroll today

If you have any questions, need assistance, or want to report a bug, please contact our support team by creating a ticket via this link.

Kind regards,

Footer banner